What is perflutren? A guide to the ultrasound contrast agent

5 min read

Perflutren is an ultrasound contrast agent composed of gas-filled microspheres that significantly enhance the quality of echocardiograms, particularly for patients with suboptimal imaging. The medication works by reflecting sound waves, providing a clearer, more detailed picture of the heart's chambers and endocardial borders.

Quick Summary

Perflutren is an ultrasound contrast agent used to improve echocardiogram quality. Administered intravenously, it consists of gas-filled microspheres that reflect sound waves for clearer cardiac imaging, aiding diagnosis.

Key Points

  • Ultrasound Contrast Agent: Perflutren is a medication used to enhance ultrasound images, specifically during echocardiograms.

  • Gas-Filled Microspheres: It consists of tiny, gas-filled microbubbles that are injected intravenously and reflect ultrasound waves to create a clearer picture of the heart's chambers.

  • Enhances Echocardiograms: Its primary use is to improve the delineation of the left ventricular endocardial border and opacify the left ventricular chamber in patients with suboptimal images.

  • Serious Cardiopulmonary Risk: A US boxed warning exists due to rare but serious or fatal cardiopulmonary reactions that can occur, especially in patients with unstable heart conditions.

  • Brand Names: Common commercial products include Definity (with a lipid shell) and Optison (with a protein shell), both containing perflutren.

  • Monitored Administration: Due to safety concerns, perflutren must be administered by trained healthcare professionals under close monitoring for at least 30 minutes post-injection.

In This Article

What is perflutren?

Perflutren is a type of ultrasound contrast agent (UCA), which is a diagnostic medication used to improve the quality of images from ultrasound procedures. Specifically, perflutren helps to enhance the visualization of the heart's structures during an echocardiogram. The agent is administered intravenously and consists of tiny, gas-filled microspheres encapsulated by a stabilizing shell. When exposed to ultrasound waves, these microspheres resonate and reflect the sound waves more efficiently than blood, producing a stronger signal that is converted into a clearer image by the ultrasound machine.

Perflutren has been approved by the FDA for use in both adult and pediatric patients with suboptimal echocardiograms to opacify the left ventricular chamber and improve the delineation of the left ventricular endocardial border. This capability allows physicians to obtain better diagnostic information in cases where standard ultrasound images are not clear enough to make an accurate diagnosis.

The Mechanism of Acoustic Enhancement

At its core, perflutren’s efficacy lies in its unique physical properties. The medication consists of a perfluorocarbon gas, octafluoropropane, contained within a microscopic shell. The shell is typically made of either phospholipids (in products like Definity) or protein (in Optison).

Here is a breakdown of the process:

  1. Preparation: Before administration, the vial containing the perflutren microspheres must be activated, usually by mechanical shaking, to form a stable suspension.
  2. Injection: The suspension is injected intravenously into the patient's bloodstream.
  3. Circulation: The microspheres travel throughout the cardiovascular system, including the heart's chambers.
  4. Resonance and Reflection: When high-frequency sound waves from the ultrasound transducer strike these microbubbles, they cause the bubbles to oscillate or resonate. This physical reaction generates a powerful reflective signal, known as an 'echo'.
  5. Improved Visualization: The enhanced signals returned by the microspheres significantly increase the brightness (echogenicity) of the blood pool, providing a stark contrast against the darker heart muscle. This clarifies the inner borders of the heart, which are difficult to see in suboptimal, non-contrast echocardiograms.

This mechanism allows for better assessment of cardiac function and structure, aiding in the diagnosis of various heart conditions.

Primary Uses in Medical Imaging

Perflutren is primarily used in cardiology to improve the diagnostic quality of echocardiograms. Its main purpose is to address the challenge of suboptimal images, which can occur due to factors such as obesity, chronic lung disease, or other conditions that interfere with ultrasound wave transmission.

Applications include:

  • Left Ventricular Opacification: Providing a clearer image of the left ventricular chamber to assess its size and volume accurately.
  • Endocardial Border Delineation: Clearly defining the inner lining of the heart's main pumping chamber, which is crucial for evaluating wall motion abnormalities and assessing overall heart function.
  • Stress Echocardiography: During a stress test (induced by exercise or medication), perflutren can be used to improve image quality, helping clinicians identify areas of the heart muscle that are not receiving adequate blood flow under stress (ischemia).

Comparing Perflutren-based Contrast Agents

While perflutren is the active ingredient, different products utilize distinct stabilizing shells. The two major FDA-approved products containing perflutren are Definity and Optison. Here is a comparison of their key features:

Feature Definity (Perflutren Lipid Microsphere) Optison (Perflutren Protein-Type A Microsphere) Other Contrast Agents (e.g., agitated saline)
Core Gas Octafluoropropane ($C_3F_8$) Octafluoropropane ($C_3F_8$) Air or other gases
Microsphere Shell Lipid shell composed of phospholipids Protein (human albumin) shell No stabilizing shell; gas bubbles are less stable and short-lived
Key Excipient Contains polyethylene glycol (PEG) PEG-free Not applicable
Shelf Life Refrigerated vial requires mechanical agitation before use; activated suspension has a limited lifespan Refrigerated vial requires resuspension before injection; has a limited time for use Used immediately upon preparation
Primary Use Left ventricular opacification and endocardial border delineation Left ventricular opacification and endocardial border delineation Less robust opacification; mainly for detecting intracardiac shunts
Signal Persistence Longer duration of contrast enhancement compared to agitated saline Longer duration of contrast enhancement compared to agitated saline Transient, brief contrast enhancement

Pharmacology and Elimination

The pharmacokinetic profile of perflutren is determined by its two components: the perflutren gas and the microsphere shell. The octafluoropropane gas is not metabolized by the body. Instead, after the microspheres are destroyed by ultrasound or collapse naturally, the gas is rapidly eliminated from the body via exhalation. The pulmonary elimination half-life is very short, typically just over a minute in healthy patients. The phospholipid or protein components of the shell are metabolized through normal physiological pathways.

Safety Profile and Considerations

Despite its effectiveness, perflutren, like other contrast agents, carries important safety considerations. For certain formulations, the FDA has issued a boxed warning concerning serious cardiopulmonary reactions that can occur during or shortly after administration.

  • Serious Cardiopulmonary Reactions: Uncommonly, patients have experienced severe or even fatal events, including cardiac arrest, respiratory arrest, shock, and arrhythmias, typically within 30 minutes of injection. The risk is heightened in patients with pre-existing unstable cardiopulmonary conditions such as a recent heart attack, unstable congestive heart failure, or serious ventricular arrhythmias.
  • Allergic Reactions: Anaphylactoid reactions, including shock, hives, swelling, and difficulty breathing, have been reported. Some reactions have been linked to polyethylene glycol (PEG) found in certain formulations, while others have been attributed to non-PEG components.
  • Common Side Effects: More frequently, patients may experience less severe side effects such as headache, dizziness, nausea, flushing, or pain at the injection site.

Due to these risks, perflutren administration must be performed under the direct supervision of trained medical professionals, with resuscitation equipment readily available. Patients are typically monitored for at least 30 minutes after receiving the contrast agent.

For more detailed product labeling and safety information, consult the official FDA resources.

Conclusion: A Critical Tool for Cardiac Diagnosis

Perflutren has revolutionized cardiac ultrasound by enabling clinicians to obtain high-quality, clear images of the heart even when traditional echocardiography fails. The medication's mechanism, which involves gas-filled microspheres reflecting sound waves, significantly enhances the visualization of cardiac structures like the left ventricular chamber and endocardial borders. While associated with a risk of rare but serious cardiopulmonary and allergic reactions, the benefits for diagnostic accuracy often outweigh the risks, particularly in patients with suboptimal baseline images. Administered intravenously by trained professionals under careful monitoring, perflutren-based agents like Definity and Optison continue to be a vital adjunctive tool in the practice of modern cardiology, providing crucial information for assessing heart function and diagnosing cardiac disease.

Frequently Asked Questions

Perflutren is an ultrasound contrast agent used to enhance echocardiograms, specifically to improve the visualization of the heart's left ventricular chamber and endocardial borders in patients where standard ultrasound images are unclear.

Perflutren is administered intravenously (into a vein) by a healthcare professional as either a bolus injection or a continuous infusion.

The medication contains tiny, gas-filled microbubbles. When these microbubbles circulate through the heart and are hit by ultrasound waves, they resonate and reflect the sound waves brightly, creating a high-contrast image.

Common side effects include headache, dizziness, flushing, and nausea. Less common side effects can include chest pain or reactions at the injection site.

The boxed warning highlights the risk of serious cardiopulmonary reactions, including fatal events, that can occur shortly after administration. The risk is higher in patients with unstable heart or lung conditions.

Perflutren should not be used in patients with an unstable cardiopulmonary status, such as recent heart attack, unstable heart failure, or severe heart rhythm problems. Patients with a known allergy to perflutren or its components should also avoid it.

The gas component, octafluoropropane, is not metabolized and is eliminated rapidly from the body via the lungs when exhaled.

No, while both contain perflutren, they use different stabilizing shells. Definity uses a lipid shell and contains PEG, while Optison uses a human albumin (protein) shell and is PEG-free.

References

  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6