Skip to content

What is the Risk of Coring a Vial? Understanding Dangers and Prevention

4 min read

The incidence of medication vial coring has been reported to vary widely, with some studies indicating a potential for fragmented material to be injected into patients. For clinicians and patients alike, understanding what is the risk of coring a vial is paramount to preventing potential harm.

Quick Summary

Vial coring occurs when a needle shears a piece of the rubber stopper, which can contaminate injectable medication. Unseen rubber fragments can be injected into a patient, leading to serious adverse events such as embolism, infection, or localized tissue damage.

Key Points

  • Embolism Risk: In intravenous administration, injected rubber fragments can act as emboli, potentially causing a stroke or myocardial infarction.

  • Local Tissue Damage: Subcutaneous or intramuscular injections with cored fragments can lead to localized inflammation, abscesses, or granuloma formation.

  • Increased Risk Factors: Blunt needles, larger gauge needles, and repeated punctures of the same vial stopper significantly increase the likelihood of coring.

  • Prevention Techniques: To minimize the risk, use sharp, small-gauge needles, employ correct insertion technique, and consider alternatives like filter needles or vial adapters.

  • Respond to Coring: If a core is observed, immediately discard both the vial and the syringe, and report the incident to prevent accidental use.

  • Manufacturer Variations: The physical properties of vial stoppers can vary, influencing the risk of coring depending on the manufacturer and materials used.

In This Article

What is Vial Coring?

Vial coring is a phenomenon that occurs during the preparation of injectable medications. It is defined as the shearing of a small piece of the flexible rubber stopper of a medication vial by the tip of a needle during insertion. This small fragment, or "core," can then fall into the liquid medication inside the vial. Due to its often minuscule size, the core can be difficult to see and may be drawn into the syringe along with the medication, creating a serious patient safety hazard.

Causes of Coring

Several factors can contribute to the risk of coring, ranging from technique-related issues to the properties of the vial itself.

Technique and User Factors:

  • Needle Type and Gauge: Using blunt needles or larger gauge needles (e.g., 18-gauge) increases the likelihood of coring, as they require more force to puncture the stopper. Sharp, smaller-gauge needles are generally preferred.
  • Repeated Punctures: The more a vial stopper is accessed, the weaker the rubber becomes, significantly increasing the risk of coring.
  • Force of Puncture: Excessive or uncontrolled force during insertion can cause fragmentation.
  • Angle of Puncture: While an angled approach (e.g., 45-60 degrees) is sometimes recommended, recommendations are inconsistent, and data is limited. An optimal angle minimizes resistance during puncture.

Vial and Stopper Factors:

  • Elastomer Formulation: The material composition of the stopper affects its functional properties. Some materials, like synthetic isoprene, may offer more robust functional properties and reduced coring compared to others.
  • Stopper Thickness and Siliconization: The thickness of the stopper diaphragm and the consistency of its siliconization can influence the likelihood of fragmentation.

Understanding the Risk of Coring a Vial to Patients

When a rubber core is inadvertently injected into a patient, it can lead to severe and potentially life-threatening complications. The specific risks depend on the route of administration, highlighting the importance of understanding the potential impact across various clinical settings.

Risks for Intravenous (IV) Administration

  • Embolism: A rubber core injected into the bloodstream can act as an embolus, potentially blocking a critical blood vessel. This can lead to serious cardiovascular events, such as a myocardial infarction (heart attack) or stroke.
  • Infection: If aseptic technique is compromised during the coring incident, contaminated material can enter the bloodstream and cause a systemic infection or septicemia.
  • Inflammatory Response: The body's immune system may treat the rubber particle as a foreign invader, triggering a systemic inflammatory response or a localized issue like phlebitis (inflammation of the vein).

Risks for Subcutaneous (SC) and Intramuscular (IM) Administration

  • Localized Inflammatory Reactions: Fragments of the rubber stopper can cause localized inflammation, swelling, and pain at the injection site.
  • Granuloma Formation: The immune system can wall off the foreign particle, leading to the formation of a granuloma, which can manifest as persistent nodules or lumps under the skin or in muscle tissue.
  • Tissue Damage: Injection of fragments into muscle tissue can cause trauma and lead to abscess formation, pain, and impaired muscle function.

Best Practices to Minimize Coring

Preventing coring is a crucial patient safety measure. Healthcare providers can significantly reduce the risk by adopting specific techniques and utilizing appropriate equipment.

  • Use Proper Needles: Always use sharp, sterile needles. Avoid blunt needles unless specific manufacturer instructions recommend them. Opt for smaller gauge needles (e.g., 21-gauge) over larger ones (e.g., 18-gauge) when clinically appropriate.
  • Use Correct Insertion Technique: When accessing a vial, use a controlled, smooth motion. While the optimal angle is debated, many suggest an angled approach (45-60 degrees) that creates the least resistance.
  • Limit Punctures: Puncture the vial stopper only once whenever possible to maintain the integrity of the rubber.
  • Consider Alternatives: For high-risk medications or techniques, consider using alternatives like filter needles or vial adapters to avoid direct contact with the stopper and subsequent particulate matter contamination. Pre-filled syringes also eliminate the risk entirely.

Comparing Vial Access Techniques

Technique Advantages Disadvantages Coring Risk Level
Standard Aspiration Widely available, low cost. High potential for coring, especially with poor technique or large gauge needles. High
Filter Needle Prevents particulate matter from entering the syringe. Cannot be used for particulate drugs. Requires an extra step and device. Low (if used correctly)
Vial Adapter Allows for multiple withdrawals with one puncture. Reduced risk of fragmentation. Specific to vial size, higher cost per use. Very Low
Prefilled Syringe Eliminates the need for vial access and preparation entirely. May not be available for all medications; higher cost. None

Responding to a Coring Incident

If you suspect that coring has occurred, it is imperative to follow established safety protocols to protect the patient. As advised by organizations like the Anesthesia Patient Safety Foundation (APSF), the appropriate steps include:

  • Do Not Administer: If you see a fragment, or suspect that coring has occurred, do not administer the medication.
  • Discard Safely: Discard the syringe and the entire vial contents, as the medication is now contaminated.
  • Secure the Vial: Secure the contaminated vial and medication to prevent accidental use.
  • Report the Incident: Notify the pharmacy and report the incident through your facility's safety reporting system. This data helps identify trends and prevent future occurrences.
  • Obtain a New Vial: Prepare a fresh dose of medication from an uncontaminated vial, following best practices to prevent coring.

Conclusion

The risk of coring a vial poses a significant threat to patient safety through contamination and the potential injection of foreign particles. While the incidence rate can be highly variable, the consequences, including embolism and localized tissue damage, are serious. By understanding the contributing factors and adhering to best practices such as using sharp, appropriately gauged needles, proper insertion techniques, and considering safer alternatives like filter needles or vial adapters, healthcare professionals can drastically reduce the risk. Continuous education and vigilance are essential to ensuring the highest standard of patient care. In cases where coring is suspected, strict adherence to safety protocols is the only acceptable course of action. For more information on patient safety, refer to the Anesthesia Patient Safety Foundation (APSF) website.

Frequently Asked Questions

The primary danger is the risk of embolism, especially during intravenous administration, where the fragment can travel through the bloodstream and block a critical blood vessel.

Yes, the needle type is a major factor. Blunt needles and larger gauge needles are associated with a higher risk of coring compared to sharp, smaller gauge needles.

After drawing the medication, inspect the vial for visible fragments floating in the liquid. A final check of the syringe contents before administration is also recommended, although microscopic fragments can be missed.

The medication should not be administered. The entire vial and syringe contents must be discarded, the incident reported, and a fresh, uncontaminated dose prepared.

Any medication in a vial with a rubber stopper carries this risk. The incidence depends on the technique, needle, and stopper material.

Yes. Using prefilled syringes or vial adapters can either eliminate or significantly reduce the risk of coring. For certain applications, filter needles can also prevent particulate injection.